Optimal Placement of Skin Temperature Sensors in Neonates Admitted to the Neonatal Intensive Care Unit (NICU): A Review of Clinical Evidence
نویسندگان :
Somaye Pouy
1
Latif Panahi
2
Mona Hoseinzadeh Seyghalani
3
Zahra Tavakolnia
4
1- School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.
2- School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.
3- School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.
4- School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.
کلمات کلیدی :
Skin Temperature،Sensors،Neonate،Neonatal Intensive Care Unit (NICU)
چکیده :
Introduction: Thermoregulation is a physiological cornerstone in neonatal care. Neonates, especially those born preterm, possess limited thermal reserves and are susceptible to rapid heat loss or gain. Thermal instability in the NICU is not merely a metabolic concern but a significant risk factor for increased mortality, intraventricular hemorrhage, and necrotizing enterocolitis. While servo-controlled incubators rely heavily on skin temperature sensor feedback, the clinical literature reveals inconsistent practices regarding optimal sensor placement. Improper placement may result in inaccurate data, triggering compensatory responses from the incubator that may either overheat or under-cool the infant, leading to significant clinical complications. Aim: This study aimed to critically review and synthesize existing clinical evidence to identify the most accurate and reliable anatomical site for skin temperature sensor placement, considering different infant positions, maturity levels, and environmental factors in the NICU. Methods: A comprehensive systematic literature review was conducted. The search strategy utilized international databases (PubMed, Scopus, Web of Science, Cochrane Library, and CINAHL) and national Iranian databases (SID, IranDoc, and Magiran). Keywords were selected using MeSH and specialized terminology, including: “Neonatal Intensive Care,” “Skin Temperature,” “Sensor Placement,” “Thermoneutrality,” “Infant Monitoring,” “Servo-control,” “Neonatal Nursing,” and “Preterm Infants.” Inclusion criteria focused on original clinical trials, observational studies, and systematic reviews published between 2015 and 2025 that explicitly measured the correlation between peripheral skin temperature and core (rectal/esophageal) temperature. Data extraction was performed independently, and the quality of evidence was evaluated based on clinical protocols for skin perfusion and thermal conductivity. Results: The findings indicate that the mid-epigastric region, specifically the area just below the xiphoid process and above the liver, remains the gold standard for supine-positioned neonates, as it provides the most stable correlation with core body temperature. However, the evidence is increasingly challenging this “one-site-fits-all” approach. For infants in the prone position-often used to improve oxygenation-the epigastric region may lead to falsely elevated readings due to direct heat transfer from the mattress. In these cases, the flank or the scapular region provides more reliable data. Furthermore, the review identifies that placing sensors over bony prominences or areas of high local perfusion can cause significant measurement bias. We also analyzed the impact of reflective covers and incubator humidity, noting that the thermal gradient between the skin and the environment must be managed by intelligent sensor placement to prevent “thermal shock” or peripheral vasoconstriction. The evidence also highlights that nursing competency in sensor application is a major variable; poor skin contact or accidental displacement of the sensor is a frequent cause of technical alarms and patient instability. Conclusion: The findings suggest that NICU nursing protocols should transition from a standardized, static approach to a position-dependent strategy for sensor placement. While the epigastric site is prioritized for supine infants, specialized training is required for prone and laterally positioned neonates. Implementing structured competency-based education for bedside nurses regarding the physics of thermal monitoring can significantly optimize the thermal environment. Future studies should focus on integrating multi-site monitoring in extremely low birth weight (ELBW) infants to better reflect the complexity of their thermoregulatory needs.
لیست مقالات
لیست مقالات بایگانی شده
مطالعه چندبعدی رفتار دمایی، عملکردی و اجرایی قیرهای لاستیکی اصلاح شده با ترکیبات شیمیایی
امیر امینی - احسان حاجیان
پذیرش فناوریهای نوین آموزشی در آموزش های بالینی: مطالعهای مبتنی بر مدل پذیرش فناوری در رشته هوشبری
سلیمان احمدی - نرجس میرزائی سیبنی - سارا شهبازی - سجاد احمدی
Hybrid Lithium-Ion Portable Renewable Energy Storage System (ESS)
Amirhossein Rahimian Zarif - Seyed Amirreza Ghorab Baygi - Yasser Mafinejad
تفاوت های جنسیتی در پیش بینی اثر فشار شغلی بر تعهد سازمانی (مورد مطالعه: کارکنان درمانی بیمارستان امام سجاد (ع) شهر یاسوج)
زهرا مومن فر - وحید دستیار
Precision Agriculture with AI-IoT: Optimizing PGPB Biofertilizers for Yield and Sustainability
Zarrindokht Emami-Karvani
مرور نظاممند تشخیص و رهگیری هدف در پهپادها و رادارهای هوشمند: شبکههای ژرف، ادغام چندحسگری و کنترل ازدحامی
بهزاد سیف الدین هومانی - هنگامه کشاورز
مرور تحلیلی بر معماری سازمانی دادهمحور(DDEA) و قابلیت کسب وکار با تمرکز بر ارتقای تصمیمگیری هوشمند و چابکی سازمانی
محمود قاسمی - هما موحد نژاد - مهدی شریفی - حسن خیراتی
مروری بر چاپگرهای 3بعدی و 4بعدی ابری با کاربرد در تولید افزایشی
آیه موری بختیاری - بهرنگ برکتین - نغمه فرهادیان
اثربخشی استفاده از تلهمدیسین در مدیریت بیماران اورژانسی در مرحله پیشبیمارستانی مقاله مروری روایی شواهد
شایان محبی - سمانه اورک
مروری جامع بر جدید ترین روش های کاهش درد در زایمان طبیعی
نگار زراعت کار - مریم محمد احمدی - نرگس قاسمی - شقایق مریدی - یلدا شاه ولی - نسیم خادمی
بیشتر
ثمین همایش، سامانه مدیریت همایش ها و جشنواره ها - نگارش 44.12.4